Bharat Modi , Dinesh Kumar , Shubhi Jain , Mohit Kumar Sharma , Jitendra Singh , Smriti Jain
International Journal of Electrical, Electronics and Computers (IJECC), Vol-9,Issue-2, March - April 2024, Pages 1-4, 10.22161/eec.92.1
Download | Downloads : 3 | Total View : 141
Article Info: Received: 03 Mar 2024; Accepted: 15 Apr 2024; Date of Publication: 22 Apr 2024
In this paper the inverter has been simulated to operate in over-modulation region to utilize maximum of the DC bus voltage. During the operation of NPC in over-modulation zone, the output has flat topped waveform i.e. the upper part gets clipped-off because of operation in over-modulation. By considering, NPC inverter as a system based on single pole triple throw switch so that it can be applied ±0.5Vdc and zero voltage at the load terminal is achieved. The number of level counts on the basis of the line-to-line pole voltage so can also be called a 5-level inverter as we have shown, in this paper, the number of levels is equivalent to the number of pole voltages.